Resistivity and IP cross-section from the P1 profile (central part of the landfill). The IP method indicates crude oil-like anomaly in depth of roughly 5 meters (marked by ellipsis).

Pohnánec site:
Old ecological burden

Client:
Čepro a.s.

Duration:
2015 - 2020

Goals of the project:
There is a waste landfill in the place of interest, which is owned by ČEPRO a.s. The mentioned landfill fills the part of the depression with a direction of approximately N-S. The landfill contains various materials, in addition to residues from oil products, also various rubble and municipal waste (or landfill material stored without a permit). The contents of the landfill can endanger the environment and potable water sources, and therefore it was necessary to specify the shape of the depression filled with waste and to supplement the knowledge of the tectonic structure. The assignment was solved by seismic refraction, magnetometry and ERT method in variant R (resistivities) and IP (induced polarization).